Armstrong steam aware steam aware is the next generation in product sizing and selection software from armstrong, and it does everything the industrys first steam trap. Noncondensibles, such as carbon dioxide promote corrosion and other deterioration of equipment and inhibit their function. But armstrong inverted bucket traps last years longer than other traps. Trap size, operating pressure and importance determine how frequently traps should be checked. Ceiling cad files armstrong ceiling solutions commercial. Hvac fluidflow solutions armstrong fluid technology. Download files with building information modeling formats. Learn about steam traps armstrong state university. Looking for armstrong international steam trap, 34 fnpt connections, 378 end to end length, condensate capacity lbshr 1200 36y245. Armstrong international j series float and thermostatic traps. The heart of its simple design is a unique leverage. For critical installations, two traps, each of which can handle the full load, should be fitted in parallel. Study online the purpose of steam traps, explore various types, learn to size and select and identify typical maintenance and preventive measures. Cast iron for horizontal installation, with thermostatic air vent.
The inverted bucket steam trap energy efficient because its so reliable the inverted bucket is the most reliable steam trap operating principle known. The computeraided design cad files and all associated content posted to this website are created, uploaded, managed and owned by third party users. On 1800 and 2000 series stainlesssteel traps, an internal check valve cannot be installed. Always isolate steam trap from pressurized supply and return lines before opening for inspection or repair. Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam the inverted bucket principle. Increasing right along with them is the awarenessgreater than ever beforeof how important steam trap maintenance is to conserving energy and saving dollars. Learn about steam tracing armstrong state university.
An efficient armstrong steam trap wastes less energy, which means you burn less fuel and reduce emissions. When the condensate return system is not pressurized, the traps. Most steam traps are nothing more than automatic valves. Armstrong inverted bucket traps armstrong international. Armstrong s software program 1 steam trap sizing and selection is designed to be used in conjunction with handbook n101 and this catalog.
Data collected by trap test can be downloaded later to a personal computer via. Armstrong inverted bucket steam traps open and close based on the difference in density between condensate and steam. Armstrong 75a8 steam trap 2 in ds 3dcontentcentral. Spirax sarco ball float steam traps are compact and versatile, working efficiently on both light and heavy condensate loads. There are many types of steam traps, and selecting the appropriate type will depend on the specific application, such as steam. This video showcases the benefits of armstrong inverted bucket steam traps, such as. Float and thermostatic steam traps us spirax sarco.
Matching a trap to a specific drainage application must take into account the various operating principles of steam traps. We use cookies to give you the best experience on our website. The inverted bucket steam trap resistance to damage from water hammer open bucket or float will not collapse as a result of water hammer. Once generated, drawings are ready for immediate download.
For maximum trap life and steam economy, a regular schedule should be set up for trap testing and preventive maintenance. The stainless steel valve and seat of the armstrong inverted bucket steam. Armstrong offers a full range of steam traps as well as the remarkable trap valve station tvs to integrate valves and traps. Commercial ceiling cad files from armstrong ceiling solutions.
Armstrong guidelines for steam trap repair youtube. When you design a new project, steam traps certainly are not the hottest item. State supply is known by building maintenance professionals accross the nation as the premier boiler room supply superstore. To find out more about armstrong inverted bucket steam traps, download the pdf files below.
A comprehensive best practice guide to saving energy and optimising plant performance, the steam and condensate loop book is a must for all experienced engineers and an invaluable training tool to all those new to steam. Armstrong series a, ai, b, bi steam trap installation guide. Fempftasteam trap performance assessment department of. See the difference in operation between a thermostatic bimetal trap and an inverted bucket trap. Armstrong inverted bucket steam traps open and close based on the difference in. This means, in your 20year scope capital investment, each process application needs 3 to 5 new traps. Pop drain for freeze protection in general, a properly selected and installed armstrong trap will not freeze as long as steam is coming to the trap. Steam trap id charts see tables on pages st90, st92 and st94 for complete temperaturepressure rating information. Isolate strainer from pressurized system before opening to clean.
Making sure the trap fits the need armstrong international. Armstrong international 880 series inverted bucket steam traps. A steam trap is a device used to discharge condensates and noncondensable gases with a negligible consumption or loss of live steam. However we all know traps fail every 4 to 6 years on the average.
Product specification sheets cast iron inverted bucket traps download series 800, 880, 200 for pressures to 250 psig. Armstrong steam trap testing guide for energy conservation. Repairrebuild kits for various armstrong steam traps. Suggested yearly trap testing frequency operating pressure psig. Armstrongs developments and improvements in steam trap design and function have. List the different types of steam traps used on tracer lines. Product specification sheets cast iron inverted bucket traps download. List the three main applications for steam tracing. Capacities to 3,450 lbhr 1,568 kghr b a b a c h d all dimensions and weights are. All armstrong cast iron inverted bucket steam traps are repairable for even bigger maintenance savings. The results are energy savings and a cleaner, healthier environment.
Steam trapping and steam tracing equipment armstrong inc. Armstrong steam trap testing guide for energy conservation knowledge not shared is energy wasted. The armstrong 880 series inverted bucket steam traps shown below provide you with an integral strainer builtin to the base of the trap. A steam trap is a device used to discharge condensate and noncondensable gases with a negligible consumption or loss of live steam. Even if the correct operational design of steam trap is selected and installed perfectly, incorrect steam trap sizing will cause either condensate backup or steam. The charts below will help indicate which steam trap brand best suits your needs based on material, mounting and features. Operating pressure and temperature may be limited depending on the class of flange selected. Armstrong steam and condensate group, 816 maple st. The trap allows steam to enter from one side of the trap, and the condensate to discharge from the same side of the trap. For steam and hydronic systems, armstrong can provide a variety of products for use. Armstrong s new advanced platform for selecting hvac solutions. As a steam trap wears, it loses efficiency and begins to waste energy.
By helping companies manage energy, armstrong steam traps are also helping protect the world we all share. An armstrong design envelope pump combined with active performance management can make a big difference. Advanced technologies for evaluating the performance of steam traps. Armstrongs pumping traps offer all the benefits of returning condensate. Radio frequency monitoring of steam traps gives you an. These traps efficiently move condensate, air, and co 2 out of steam. Steam trap options and connectors control specialties. Millions of users download 3d and 2d cad files everyday. Armstrong steam traps are also helping protect the world we all share.
Steam traps were subsequently developed to act as an automatic valve to remove condensate. Hoffman specialty general catalog the macomb group. All the internal parts of the steam trap are boxed together for onthejob assembly. Armstrong s cvi inline check valve will solve the problem. Next tt series thermostatic steam traps all stainless steel. However, a typical steam system can be a complex network. The inverted bucket steam trap armstrong international. Matching a trap to a specific drainage application must take into account the various operating principles of steam traps as well as the specific need and conditions. Guidelines for steam trap troubleshooting and testing not only outlines the need for establishing a preventive maintenance program, but details what to look and listen for in your testing. A unique leverage system multiplies the force provided by the bucket to open the valve against system pressure. Steam traps provide the basic function of condensate removal in a steam system. By helping companies manage energy, armstrong steam traps.
1088 922 1221 1207 660 1034 854 504 657 904 1139 1641 1416 475 678 1034 439 454 1608 909 722 1364 1405 1616 620 1559 1520 1029 129 727 783 786 85 346 1257 1650 1190 826 1423 1224 677 663 1003 1044 544 280 1169 996 1141